6ES7511-1AK02-0AB0 S7-1500 CPU 1511-1 PN

17,868,000 

  • SKU: 6ES7511-1AK02-0AB0
  • Tình trạng: Hàng có sẵn, mới 100%
  • Chứng từ COCQ, tờ khai hải quan, có xuất hóa đơn VAT
  • Hãng sản xuất: Siemens
  • Giảm thêm 5% khi mua sản phẩm cùng danh mục có giá cao hơn
Chính sách ưu đãi CHÍNH SÁCH ƯU ĐÃI
Mua ngay
Mã: 6ES7511-1AK02-0AB0 Danh mục: , Thương hiệu: Siemens

Thông số kỹ thuật

6ES7511-1AK02-0AB0 sở hữu 2 cổng PROFINET, 8 phím nhấn, bộ nhớ chương trình 150KB1MB lưu trữ dữ liệu, sử dụng nguồn đầu vào 24VDC, tiêu chuẩn bảo vệ IPv4, có 1 khe cắm thẻ nhớ (thẻ nhớ phải mua kèm tùy vào dung lượng sử dụng).

General information
Product type designation CPU 1511-1 PN
HW functional status FS03
Firmware version V2.9
Product function
I&M data Yes; I&M0 to I&M3
Isochronous mode Yes; Distributed and central; with minimum OB 6x cycle of 625 µs (distributed)
and 1 ms (central)
Engineering with
STEP 7 TIA Portal configurable/integrated from version V17 (FW V2.9) / V15 (FW V2.5) or higher; with older TIA Portal versions
configurable as 6ES7511-1AK01-0AB0
Configuration control
via dataset Yes
Display
Screen diagonal [cm] 3.45 cm
Control elements
Number of keys 8
Mode buttons 2
Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Mains buffering
Mains/voltage failure stored energy time 5 ms
Repeat rate, min. 1/s
Input current
Current consumption (rated value) 0.7 A
Current consumption, max. 0.95 A
Inrush current, max. 1.9 A; Rated value
I²t 0.02 A²·s
Power
Infeed power to the backplane bus 10 W
Power consumption from the backplane bus (balanced) 5.5 W
Power loss
Power loss, typ. 5.7 W
Memory
Number of slots for SIMATIC memory card 1
SIMATIC memory card required Yes
Work memory
integrated (for program) 150 kbyte
integrated (for data) 1 Mbyte
Load memory
Plug-in (SIMATIC Memory Card), max. 32 Gbyte
Backup
maintenance-free Yes
CPU processing times
for bit operations, typ. 60 ns
for word operations, typ. 72 ns
for fixed point arithmetic, typ. 96 ns
for floating point arithmetic, typ. 384 ns
CPU-blocks
Number of elements (total) 4 000; Blocks (OB, FB, FC, DB) and UDTs
DB
Number range 1 … 60 999; subdivided into: number range that can be used by the user: 1 …
59 999, and number range of DBs created via SFC 86: 60 000 … 60 999
Size, max. 1 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
FB
Number range 0 … 65 535
Size, max. 150 kbyte
FC
Number range 0 … 65 535
Size, max. 150 kbyte
OB
Size, max. 150 kbyte
Number of free cycle OBs 100
Number of time alarm OBs 20
Number of delay alarm OBs 20
Number of cyclic interrupt OBs 20; With minimum OB 3x cycle of 500 µs
Number of process alarm OBs 50
Number of DPV1 alarm OBs 3
Number of isochronous mode OBs 2
Number of technology synchronous alarm OBs 2
Number of startup OBs 100
Number of asynchronous error OBs 4
Number of synchronous error OBs 2
Number of diagnostic alarm OBs 1
Nesting depth
per priority class 24
Counters, timers and their retentivity
S7 counter
Number 2 048
Retentivity
adjustable Yes
IEC counter
Retentivity
adjustable Yes
S7 times
Number 2 048
Retentivity
adjustable Yes
IEC timer
Number Any (only limited by the main memory)
Retentivity
adjustable Yes
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max. 128 kbyte; In total; available retentive memory for bit memories, timers,
counters, DBs, and technology data (axes): 88 KB
Extended retentive data area (incl. timers, counters, flags), max. 1 Mbyte; When using PS 6 0W 24/48/60 V DC HF
Flag
Size, max. 16 kbyte
Number of clock memories 8; 8 clock memory bit, grouped into one clock memory byte
Data blocks
Retentivity adjustable Yes
Retentivity preset No
Local data
per priority class, max. 64 kbyte; max. 16 KB per block
Address area
Number of IO modules 1 024; max. number of modules / submodules
I/O address area
Inputs 32 kbyte; All inputs are in the process image
Outputs 32 kbyte; All outputs are in the process image
per integrated IO subsystem
Inputs (volume) 8 kbyte
Outputs (volume) 8 kbyte
per CM/CP
Inputs (volume) 8 kbyte
Outputs (volume) 8 kbyte
Subprocess images
Number of subprocess images, max. 32
Hardware configuration
Number of distributed IO systems 32; A distributed I/O system is characterized not only by the integration of
distributed I/O via PROFINET or PROFIBUS communication modules, but also
by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)
Number of DP masters
Via CM 4; A maximum of 4 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be
inserted in total
Number of IO Controllers
integrated 1
Via CM 4; A maximum of 4 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be
inserted in total
Rack
Modules per rack, max. 32; CPU + 31 modules
Number of lines, max. 1
PtP CM
Number of PtP CMs the number of connectable PtP CMs is only limited by the number of available
slots
Time of day
Clock
Type Hardware clock
Backup time 6 wk; At 40 °C ambient temperature, typically
Deviation per day, max. 10 s; Typ.: 2 s
Operating hours counter
Number 16
Clock synchronization
supported Yes
in AS, master Yes
in AS, slave Yes
on Ethernet via NTP Yes
Number of PROFINET interfaces 1
1. Interface
Interface types
RJ 45 (Ethernet) Yes; X1
Number of ports 2
integrated switch Yes
Protocols
IP protocol Yes; IPv4
PROFINET IO Controller Yes
PROFINET IO Device Yes
SIMATIC communication Yes
Open IE communication Yes; Optionally also encrypted
Web server Yes
Media redundancy Yes
PROFINET IO Controller
Services
PG/OP communication Yes
Isochronous mode Yes
Direct data exchange Yes; Requirement: IRT and isochronous mode (MRPD optional)
IRT Yes
PROFIenergy Yes; per user program
Prioritized startup Yes; Max. 32 PROFINET devices
Number of connectable IO Devices, max. 128; In total, up to 256 distributed I/O devices can be connected via AS-i,
PROFIBUS or PROFINET
Of which IO devices with IRT, max. 64
Number of connectable IO Devices for RT, max. 128
of which in line, max. 128
Number of IO Devices that can be simultaneously
activated/deactivated, max.
8; in total across all interfaces
Number of IO Devices per tool, max. 8
Updating times The minimum value of the update time also depends on communication share
set for PROFINET IO, on the number of IO devices, and on the quantity of
configured user data
Update time for IRT
for send cycle of 250 µs 250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum
update time of 625 µs of the isochronous OB is decisive
for send cycle of 500 µs 500 μs to 8 ms; Note: In the case of IRT with isochronous mode, the minimum
update time of 625 µs of the isochronous OB is decisive
for send cycle of 1 ms 1 ms to 16 ms
for send cycle of 2 ms 2 ms to 32 ms
for send cycle of 4 ms 4 ms to 64 ms
With IRT and parameterization of “odd” send cycles Update time = set “odd” send clock (any multiple of 125 µs: 375 µs, 625 µs … 3
875 µs)
Update time for RT
for send cycle of 250 µs 250 µs to 128 ms
for send cycle of 500 µs 500 µs to 256 ms
for send cycle of 1 ms 1 ms to 512 ms
for send cycle of 2 ms 2 ms to 512 ms
for send cycle of 4 ms 4 ms to 512 ms
PROFINET IO Device
Services
PG/OP communication Yes
Isochronous mode No
IRT Yes
PROFIenergy Yes; per user program
Shared device Yes
Number of IO Controllers with shared device, max. 4
activation/deactivation of I-devices Yes; per user program
Asset management record Yes; per user program
Interface types
RJ 45 (Ethernet)
100 Mbps Yes
Autonegotiation Yes
Industrial Ethernet status LED Yes
Protocols
PROFIsafe No
Number of connections
Number of connections, max. 96; via integrated interfaces of the CPU and connected CPs / CMs
Number of connections reserved for ES/HMI/web 10
Number of connections via integrated interfaces 64
Number of S7 routing paths 16
Redundancy mode
H-Sync forwarding Yes
Media redundancy
Media redundancy only via 1st interface (X1)
MRP Yes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager;
MRP Client
MRP interconnection, supported Yes; as MRP ring node according to IEC 62439-2 Edition 3.0
MRPD Yes; Requirement: IRT
Switchover time on line break, typ. 200 ms; For MRP, bumpless for MRPD
Number of stations in the ring, max. 50
SIMATIC communication
PG/OP communication Yes; encryption with TLS V1.3 pre-selected
S7 routing Yes
S7 communication, as server Yes
S7 communication, as client Yes
User data per job, max. See online help (S7 communication, user data size)
Open IE communication
TCP/IP Yes
Data length, max. 64 kbyte
several passive connections per port, supported Yes
ISO-on-TCP (RFC1006) Yes
Data length, max. 64 kbyte
UDP Yes
Data length, max. 2 kbyte; 1 472 bytes for UDP broadcast
UDP multicast Yes; Max. 5 multicast circuits
DHCP Yes
DNS Yes
SNMP Yes
DCP Yes
LLDP Yes
Encryption Yes; Optional
Web server
HTTP Yes; Standard and user pages
HTTPS Yes; Standard and user pages
OPC UA
Runtime license required Yes; “Small” license required
OPC UA Client Yes
Application authentication Yes
Security policies Available security policies: None, Basic128Rsa15, Basic256Rsa15,
Basic256Sha256
User authentication “anonymous” or by user name & password
Number of connections, max. 4
Number of nodes of the client interfaces,
recommended max.
1 000
Number of elements for one call of 300
OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList,
max.
Number of elements for one call of
OPC_UA_NameSpaceGetIndexList, max.
20
Number of elements for one call of
OPC_UA_MethodGetHandleList, max.
100
Number of simultaneous calls of the client
instructions for session management, per connection,
max.
1
Number of simultaneous calls of the client
instructions for data access, per connection, max.
5
Number of registerable method calls of
OPC_UA_MethodCall, max.
100
Number of inputs/outputs when calling
OPC_UA_MethodCall, max.
20
OPC UA Server Yes; Data access (read, write, subscribe), method call, custom address space
Application authentication Yes
Security policies Available security policies: None, Basic128Rsa15, Basic256Rsa15,
Basic256Sha256
User authentication “anonymous” or by user name & password
GDS support (certificate management) Yes
Number of sessions, max. 32
Number of accessible variables, max. 50 000
Number of registerable nodes, max. 10 000
Number of subscriptions per session, max. 20
Sampling interval, min. 100 ms
Publishing interval, min. 500 ms
Number of server methods, max. 20
Number of inputs/outputs per server method, max. 20
Number of monitored items, recommended max. 1 000; for 1 s sampling interval and 1 s send interval
Number of server interfaces, max. 10 of each “Server interfaces” / “Companion specification” type and 20 of the
type “Reference namespace”
Number of nodes for user-defined server interfaces,
max.
1 000
Alarms and Conditions Yes
Number of program alarms 100
Number of alarms for system diagnostics 50
Further protocols
MODBUS Yes; MODBUS TCP
Isochronous mode
Equidistance Yes
S7 message functions
Number of login stations for message functions, max. 32
Program alarms Yes
Number of configurable program messages, max. 5 000; Program messages are generated by the “Program_Alarm” block,
ProDiag or GRAPH
Number of loadable program messages in RUN, max. 2 500
Number of simultaneously active program alarms
Number of program alarms 600
Number of alarms for system diagnostics 100
Number of alarms for motion technology objects 80
Test commissioning functions
Joint commission (Team Engineering) Yes; Parallel online access possible for up to 5 engineering systems
Status block Yes; Up to 8 simultaneously (in total across all ES clients)
Single step No
Number of breakpoints 8
Status/control
Status/control variable Yes
Variables Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
Number of variables, max.
of which status variables, max. 200; per job
of which control variables, max. 200; per job
Forcing
Forcing Yes
Forcing, variables Peripheral inputs/outputs
Number of variables, max. 200
Diagnostic buffer
present Yes
Number of entries, max. 1 000
Traces
Number of configurable Traces 4; Up to 512 KB of data per trace are possible
Interrupts/diagnostics/status information
Diagnostics indication LED
RUN/STOP LED Yes
ERROR LED Yes
MAINT LED Yes
STOP ACTIVE LED Yes
Connection display LINK TX/RX Yes
Supported technology objects
Motion Control Yes; Note: The number of technology objects affects the cycle time of the PLC
program; selection guide via the TIA Selection Tool
Number of available Motion Control resources for
technology objects
800
Required Motion Control resources
per speed-controlled axis 40
per positioning axis 80
per synchronous axis 160
per external encoder 80
per output cam 20
per cam track 160
per probe 40
Positioning axis
Number of positioning axes at motion control cycle
of 4 ms (typical value)
5
Number of positioning axes at motion control cycle
of 8 ms (typical value)
10
Controller
PID_Compact Yes; Universal PID controller with integrated optimization
PID_3Step Yes; PID controller with integrated optimization for valves
PID-Temp Yes; PID controller with integrated optimization for temperature
Counting and measuring
High-speed counter Yes
Ambient conditions
Ambient temperature during operation
horizontal installation, min. -25 °C; No condensation
horizontal installation, max. 60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the
display is switched off
vertical installation, min. -25 °C; No condensation
vertical installation, max. 40 °C; Display: 40 °C, at an operating temperature of typically 40 °C, the
display is switched off
Ambient temperature during storage/transportation
min. -40 °C
max. 70 °C
Altitude during operation relating to sea level
Installation altitude above sea level, max. 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
configuration / header
configuration / programming / header
Programming language
LAD Yes
FBD Yes
STL Yes
SCL Yes
GRAPH Yes
Know-how protection
User program protection/password protection Yes
Copy protection Yes
Block protection Yes
Access protection
protection of confidential configuration data Yes
Password for display Yes
Protection level: Write protection Yes
Protection level: Complete protection Yes
programming / cycle time monitoring / header
lower limit adjustable minimum cycle time
upper limit adjustable maximum cycle time
Dimensions
Width 35 mm
Height 147 mm
Depth 129 mm
Weights
Weight, approx. 405 g

Download tài liệu PLC S7-1500

PLC S7-1500 Catalogue

Mô tả sản phẩm

Video -6ES7511-1AK02-0AB0 S7-1500 CPU 1511-1 PN

Mua thiết bị 6ES7511-1AK02-0AB0 chính hãng ở đâu ?

Bạn có nhu cầu mua S7-1500 CPU 1511-1 PN – 6ES7511-1AK02-0AB0 hoặc mong muốn được tư vấn chi tiết hơn về sản phẩm vui lòng liên hệ công ty chúng tôi theo thông tin sau:

➢ Hotline: 0812778899 / 0969600261

➢ Email: info@thanhthienphu.vn

➢ Website: Thanhthienphu.vn

Chính sách bán hàng

✔ Chấp nhận nhiều phương thức thanh toán

✔ Hỗ trợ công nợ lên đến 30 ngày

✔ Giữ nguyên giá sản phẩm trong thời gian dài

✔ Đội ngũ nhân viên luôn sẵn sàng phục vụ 24/7

✔ Đổi trả nhanh khi thiết bị gặp vấn đề

✔ Thiết bị luôn có năm sản xuất mới nhất