Bảng thông số kỹ thuật của 6ES7212-1AE40-0XB0 :
General information | |
Product type designation | CPU 1212C DC/DC/DC |
Firmware version | V4.6 |
Engineering with | |
Programming package | STEP 7 V18 or higher |
Supply voltage | |
Rated value (DC) | |
24 V DC | Yes |
permissible range, lower limit (DC) | 20.4 V |
permissible range, upper limit (DC) | 28.8 V |
Reverse polarity protection | Yes |
Load voltage L+ | |
Rated value (DC) | 24 V |
permissible range, lower limit (DC) | 20.4 V |
permissible range, upper limit (DC) | 28.8 V |
Input current | |
Current consumption (rated value) | 400 mA; CPU only |
Current consumption, max. | 1 200 mA; CPU with all expansion modules |
Inrush current, max. | 12 A; at 28.8 V DC |
I²t | 0.5 A²·s |
Output current | |
for backplane bus (5 V DC), max. | 1 000 mA; Max. 5 V DC for SM and CM |
Encoder supply | |
24 V encoder supply | |
24 V | L+ minus 4 V DC min. |
Power loss | |
Power loss, typ. | 9 W |
Memory | |
Work memory | |
integrated | 100 kbyte |
Load memory | |
integrated | 2 Mbyte |
Plug-in (SIMATIC Memory Card), max. | with SIMATIC memory card |
Backup | |
present | Yes |
maintenance-free | Yes |
without battery | Yes |
CPU processing times | |
for bit operations, typ. | 0.08 µs; / instruction |
for word operations, typ. | 1.7 µs; / instruction |
for floating point arithmetic, typ. | 2.3 µs; / instruction |
CPU-blocks | |
Number of blocks (total) | DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used |
OB | |
Number, max. | Limited only by RAM for code |
Data areas and their retentivity | |
Retentive data area (incl. timers, counters, flags), max. | 14 kbyte |
Flag | |
Size, max. | 4 kbyte; Size of bit memory address area |
Local data | |
per priority class, max. | 16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB |
Address area | |
Process image | |
Inputs, adjustable | 1 kbyte |
Outputs, adjustable | 1 kbyte |
Hardware configuration | |
Number of modules per system, max. | 3 comm. modules, 1 signal board, 2 signal modules |
Time of day | |
Clock | |
Hardware clock (real-time) | Yes |
Backup time | 480 h; Typical |
Deviation per day, max. | ±60 s/month at 25 °C |
Digital inputs | |
Number of digital inputs | 8; Integrated |
of which inputs usable for technological functions | 6; HSC (High Speed Counting) |
Source/sink input | Yes |
Number of simultaneously controllable inputs | |
all mounting positions | |
up to 40 °C, max. | 8 |
Input voltage | |
Rated value (DC) | 24 V |
for signal “0” | 5 V DC at 1 mA |
for signal “1” | 15 V DC at 2.5 mA |
Input delay (for rated value of input voltage) | |
for standard inputs | |
parameterizable | 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four |
at “0” to “1”, min. | 0.2 ms |
at “0” to “1”, max. | 12.8 ms |
for interrupt inputs | |
parameterizable | Yes |
for technological functions | |
parameterizable | Single phase: 3 @ 100 kHz & 3 @ 30 kHz, differential: 3 @ 80 kHz & 3 @ 30 kHz |
Cable length | |
shielded, max. | 500 m; 50 m for technological functions |
unshielded, max. | 300 m; for technological functions: No |
Digital outputs | |
Number of digital outputs | 6 |
of which high-speed outputs | 4; 100 kHz Pulse Train Output |
Limitation of inductive shutdown voltage to | L+ (-48 V) |
Switching capacity of the outputs | |
with resistive load, max. | 0.5 A |
on lamp load, max. | 5 W |
Output voltage | |
for signal “0”, max. | 0.1 V; with 10 kOhm load |
for signal “1”, min. | 20 V |
Output current | |
for signal “1” rated value | 0.5 A |
for signal “0” residual current, max. | 0.1 mA |
Output delay with resistive load | |
“0” to “1”, max. | 1 µs |
“1” to “0”, max. | 5 µs |
Switching frequency | |
of the pulse outputs, with resistive load, max. | 100 kHz |
Relay outputs | |
Number of relay outputs | 0 |
Cable length | |
shielded, max. | 500 m |
unshielded, max. | 150 m |
Analog inputs | |
Number of analog inputs | 2 |
Input ranges | |
Voltage | Yes |
Input ranges (rated values), voltages | |
0 to +10 V | Yes |
Input resistance (0 to 10 V) | ≥100k ohms |
Cable length | |
shielded, max. | 100 m; twisted and shielded |
Analog outputs | |
Number of analog outputs | 0 |
Analog value generation for the inputs | |
Integration and conversion time/resolution per channel | |
Resolution with overrange (bit including sign), max. | 10 bit |
Integration time, parameterizable | Yes |
Conversion time (per channel) | 625 µs |
Encoder | |
Connectable encoders | |
2-wire sensor | Yes |
1. Interface | |
Interface type | PROFINET |
Isolated | Yes |
automatic detection of transmission rate | Yes |
Autonegotiation | Yes |
Autocrossing | Yes |
Interface types | |
RJ 45 (Ethernet) | Yes |
Number of ports | 1 |
integrated switch | No |
Protocols | |
PROFINET IO Controller | Yes |
PROFINET IO Device | Yes |
SIMATIC communication | Yes |
Open IE communication | Yes; Optionally also encrypted |
Web server | Yes |
Media redundancy | No |
PROFINET IO Controller | |
Transmission rate, max. | 100 Mbit/s |
Services | |
PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
Isochronous mode | No |
IRT | No |
PROFIenergy | No |
Prioritized startup | Yes |
Number of IO devices with prioritized startup, max. | 16 |
Number of connectable IO Devices, max. | 16 |
Number of connectable IO Devices for RT, max. | 16 |
of which in line, max. | 16 |
Activation/deactivation of IO Devices | Yes |
Number of IO Devices that can be simultaneously activated/deactivated, max. |
8 |
Updating time | The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data. |
PROFINET IO Device | |
Services | |
PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
Isochronous mode | No |
IRT | No |
PROFIenergy | Yes |
Shared device | Yes |
Number of IO Controllers with shared device, max. | 2 |
Protocols | |
Supports protocol for PROFINET IO | Yes |
PROFIsafe | No |
PROFIBUS | Yes; CM 1243-5 (master) or CM 1242-5 (slave) required |
OPC UA | Yes; OPC UA Server |
AS-Interface | Yes; CM 1243-2 required |
Protocols (Ethernet) | |
TCP/IP | Yes |
DHCP | No |
SNMP | Yes |
DCP | Yes |
LLDP | Yes |
Redundancy mode | |
Media redundancy | |
MRP | No |
MRPD | No |
SIMATIC communication | |
S7 routing | Yes |
Open IE communication | |
TCP/IP | Yes |
Data length, max. | 8 kbyte |
several passive connections per port, supported | Yes |
ISO-on-TCP (RFC1006) | Yes |
Data length, max. | 8 kbyte |
UDP | Yes |
Data length, max. | 1 472 byte |
Web server | |
supported | Yes |
User-defined websites | Yes |
OPC UA | |
Runtime license required | Yes; “Basic” license required |
OPC UA Server | Yes; data access (read, write, subscribe), method call, runtime license required |
Application authentication | Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 |
User authentication | “anonymous” or by user name & password |
Number of sessions, max. | 10 |
Number of subscriptions per session, max. | 5 |
Sampling interval, min. | 100 ms |
Publishing interval, min. | 200 ms |
Number of server methods, max. | 20 |
Number of monitored items, recommended max. | 1 000 |
Number of server interfaces, max. | 2 |
Number of nodes for user-defined server interfaces, max. |
2 000 |
Further protocols | |
MODBUS | Yes |
communication functions / header | |
S7 communication | |
supported | Yes |
as server | Yes |
as client | Yes |
User data per job, max. | See online help (S7 communication, user data size) |
Number of connections | |
overall | PG Connections: 4 reserved / 4 max; HMI Connections: 12 reserved / 18 max; |
S7 Connections: 8 reserved / 14 max; Open User Connections: 8 reserved / 14 max; Web Connections: 2 reserved / 30 max; OPC UA Connections: 0 reserved |
|
/ 10 max; Total Connections: 34 reserved / 64 max | |
Test commissioning functions | |
Status/control | |
Status/control variable | Yes |
Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
Forcing | |
Forcing | Yes |
Diagnostic buffer | |
present | Yes |
Traces | |
Number of configurable Traces | 2 |
Memory size per trace, max. | 512 kbyte |
Interrupts/diagnostics/status information | |
Diagnostics indication LED | |
RUN/STOP LED | Yes |
ERROR LED | Yes |
MAINT LED | Yes |
Integrated Functions | |
Frequency measurement | Yes |
controlled positioning | Yes |
Number of position-controlled positioning axes, max. | 8 |
Number of positioning axes via pulse-direction interface | 4; With integrated outputs |
PID controller | Yes |
Number of alarm inputs | 4 |
Number of pulse outputs | 4 |
Limit frequency (pulse) | 100 kHz |
Potential separation | |
Potential separation digital inputs | |
Potential separation digital inputs | No |
between the channels, in groups of | 1 |
Potential separation digital outputs | |
Potential separation digital outputs | Yes |
between the channels | No |
between the channels, in groups of | 1 |
EMC | |
Interference immunity against discharge of static electricity | |
Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 |
Yes |
Test voltage at air discharge | 8 kV |
Test voltage at contact discharge | 6 kV |
Interference immunity to cable-borne interference | |
Interference immunity on supply lines acc. to IEC 61000- 4-4 |
Yes |
Interference immunity on signal cables acc. to IEC 61000- 4-4 |
Yes |
Interference immunity against voltage surge | |
Interference immunity on supply lines acc. to IEC 61000- 4-5 |
Yes |
Interference immunity against conducted variable disturbance induced by high-frequency fields | |
Interference immunity against high-frequency radiation acc. to IEC 61000-4-6 |
Yes |
Emission of radio interference acc. to EN 55 011 | |
Limit class A, for use in industrial areas | Yes; Group 1 |
Limit class B, for use in residential areas | Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 |
Degree and class of protection | |
IP degree of protection | IP20 |
Standards, approvals, certificates | |
CE mark | Yes |
UL approval | Yes |
cULus | Yes |
FM approval | Yes |
RCM (formerly C-TICK) | Yes |
KC approval | Yes |
Marine approval | Yes |
Ambient conditions | |
Free fall | |
Fall height, max. | 0.3 m; five times, in product package |
Ambient temperature during operation | |
min. | -20 °C |
max. | 60 °C; Number of simultaneously activated inputs or outputs 4 or 3 (no adjacent points) at 60 °C horizontal or 50 °C vertical, 8 or 6 at 55 °C horizontal or 45 °C vertical |
horizontal installation, min. | -20 °C |
horizontal installation, max. | 60 °C |
vertical installation, min. | -20 °C |
vertical installation, max. | 50 °C |
Ambient temperature during storage/transportation | |
min. | -40 °C |
max. | 70 °C |
Air pressure acc. to IEC 60068-2-13 | |
Operation, min. | 795 hPa |
Operation, max. | 1 080 hPa |
Storage/transport, min. | 660 hPa |
Storage/transport, max. | 1 080 hPa |
Altitude during operation relating to sea level | |
Installation altitude, min. | -1 000 m |
Installation altitude, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
Relative humidity | |
Operation, max. | 95 %; no condensation |
Vibrations | |
Vibration resistance during operation acc. to IEC 60068- 2-6 |
2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail |
Operation, tested according to IEC 60068-2-6 | Yes |
Shock testing | |
tested according to IEC 60068-2-27 | Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms |
Pollutant concentrations | |
SO2 at RH < 60% without condensation | S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free |
configuration / header | |
configuration / programming / header | |
Programming language | |
LAD | Yes |
FBD | Yes |
SCL | Yes |
Know-how protection | |
User program protection/password protection | Yes |
Copy protection | Yes |
Block protection | Yes |
Access protection | |
protection of confidential configuration data | Yes |
Protection level: Write protection | Yes |
Protection level: Read/write protection | Yes |
Protection level: Complete protection | Yes |
programming / cycle time monitoring / header | |
adjustable | Yes |
Dimensions | |
Width | 90 mm |
Height | 100 mm |
Depth | 75 mm |
Weights | |
Weight, approx. | 370 g |
last modified: | 3/12/2024 |