RVP350

18,657,000 

  • SKU: S55370-C137
  • Mô tả: Heating controller for 1 heating circuit and d.h.w.
  • Tình trạng: Hàng có sẵn, mới 100%
  • Chứng từ COCQ, tờ khai hải quan, có xuất hóa đơn VAT
  • Hãng sản xuất: Siemens
  • Giảm thêm 5% khi mua sản phẩm cùng danh mục có giá cao hơn
Chính sách ưu đãi CHÍNH SÁCH ƯU ĐÃI
Mua ngay
Mã: S55370-C137 Danh mục: Thương hiệu: Siemens

Thông số kỹ thuật S55370-C137

  • Operating voltage: AC 230 V
  • Frequency: 50 Hz
  • Power consumption: 7 VA
  • Analog input, signal: LG-Ni1000 , NTC 575
  • Digital inputs: Status contact
  • Relay output, switching voltage: AC 24...230 V
  • Relay output, switching current: 2 x 2(2) A, 7 x 1(1) A
  • Degree of protection: IP40
  • Dimensions (W x H x D): 144 x 96 x 109 mm
  • Warranty: 24 Months

Mô tả sản phẩm

Weather-compensated flow temperature control of heating circuit with or without room influence, d.h.w. heating and demand based boiler temperature control.

Key functions
In addition to the functions of the RVP340, the RVP350 provides the following:

  • 3 preprogrammed plant types can be selected, with automatic assignment of the functions required for each plant type
  • Weather-compensated flow temperature control through control of valve (mixing) in a heating circuit
  • Demand based control of the boiler temperature through control of the burner
  • D.h.w. heating with charging pump, electric immersion heater and solar collector

D.h.w. control
D.h.w. control independent of the heating circuit. Control can be enabled as follows:

  • According to its own 7-day program
  • According to the program of the heating circuit
  • According to the programs of the zone controllers on the data bus
  • Permanently (24 hours a day)

D.h.w. heating features a legionella function, which can be deactivated. Legionella protection is activated once a week. The d.h.w. temperature is acquired with sensors or thermostats.

Boiler temperature control
Boiler temperature control operates as demand-dependent 2-position control. The boiler temperature is controlled through cycling of a 1- or a 2-stage burner (direct burner control). When there is no heat request, the boiler will either be shut down or maintained at the minimum temperature (selectable). Both minimum and maximum limitation of the boiler temperature are adjustable.

Nhiều người tìm kiếm

Chính sách bán hàng

✔ Chấp nhận nhiều phương thức thanh toán

✔ Hỗ trợ công nợ lên đến 30 ngày

✔ Giữ nguyên giá sản phẩm trong thời gian dài

✔ Đội ngũ nhân viên luôn sẵn sàng phục vụ 24/7

✔ Đổi trả nhanh khi thiết bị gặp vấn đề

✔ Thiết bị luôn có năm sản xuất mới nhất