- 8 inputs for DC or AC in the range from 12 to 230 V
- 8 relay contact outputs locked in pairs against each other for controlling 4 × AC 230 V sunblind drives
- Contact rated voltage AC 230 V
- Contact rated current 6 A, p.f. = 1
- Electronics powered by a AC 230 V integrated power supply
- Device functional even without bus connection or if the bus communication fails
- Preset on delivery for direct output control for each blind button function via momentary contact switches connected to the inputs
- Key for switching between bus and direct mode
- Button for each relay contact output, for switching the output in direct mode
- Selectable function for each input when using the ETS:
– Switching status, send binary value
– Switching on leading edge, switching Short/Long
– 1-pushbutton dimming, sunblind control, group control
– 1-bit/8-bit scene control
– 8-bit/16-bit value leading edge, Short/Long
– 16-bit floating point value leading edge, Short/Long
- Or for each pair of inputs:
– Acting directly on the corresponding outputs as blind button
– 2-button dimming with stop telegram or with cyclical sending
– 2-pushbutton sunblind control
- Selectable blocking of each input via a corresponding blocking object
- Sending of input objects after change
- Selectable cyclical input object sending
- Individual or shared configuration of actuator channels
- Communication objects for each blind channel for driving the sun protection into the end positions or for stopping the procedure and adjusting the blind slats in steps
- Communication objects for setting position of slats and blinds in percentage information
- Automatic opening of the blind slats to a preconfigured nominal setting after uninterrupted driving down of the blind from the top to the bottom end position, with integrated 1-bit scene control for storing and calling up (reproduction) of 2 interim blind and slat settings
- Integrated 1-bit/8-bit scene control, 8 scenes can be integrated per channel
- Optional “Sun” object for integration in a sunlight tracking control system
- Differentiation between automatic and manual mode and with automatic switchover from automatic to manual mode for the channel in question by pressing a bus button for manual control of the corresponding sun protection
- Manual mode taking precedence over automatic position commands
- Optional central command for each device or each channel for switching the relevant channels to automatic mode and driving the sun protection into the up or down end position
- Alarm: move to safety position, Locking in this position for as long as alarm is active
- Travel lock (e. g. for cleaning the outer shutter/blinds)
- Status objects for each channel for querying or for automatic sending of sun protection and slat settings as a percentage value
- Optional status objects for reporting that the up or down position has been reached
- Integrated bus coupling unit, Bus connection via bus terminal or contact system to data rail
- Modular installation devices for mounting on TH35 EN 60715 mounting rail