RVD250-A

16,385,000 

  • SKU: S55370-C125
  • Mô tả: Controller‚ 28 programmed plant types, instructions in de, en, fr, it, da, fi, sv
  • Tình trạng: Hàng có sẵn, mới 100%
  • Chứng từ COCQ, tờ khai hải quan, có xuất hóa đơn VAT
  • Hãng sản xuất: Siemens
  • Giảm thêm 5% khi mua sản phẩm cùng danh mục có giá cao hơn
Chính sách ưu đãi CHÍNH SÁCH ƯU ĐÃI
Mua ngay
Mã: S55370-C125 Danh mục: Thương hiệu: Siemens

Thông số kỹ thuật S55370-C125

  • Operating voltage: AC 230 V
  • Frequency: 50 Hz
  • Power consumption: 5.5 VA
  • Communication: LPB (interconnected controller) , M-bus (slave)
  • Analog input, signal: DC 0...10 V, LG-Ni1000 , NTC 575
  • Digital inputs, number: 1
  • Digital inputs: Pulse transmitter , Status contact
  • Digital outputs: 1 × PWM, DC 12 V, 2 × AC 230 V 2(2) A, 8 × AC 230 V 1(1) A
  • Dimensions (W x H x D): 144 x 96 x 109 mm
  • Warranty: 24 Months

Mô tả sản phẩm

Multifunctional heating controller for use in district heating substations and district heating plants with LPB and M-bus communication. Suited for one heating circuit with d.h.w. heating in instantaneous systems or with storage tank. 28 programmed plant types. Operating voltage AC 230 V.

Key features:

  • Optimized for low return temperatures in district heating networks.
  • Display of time of day‚ time program‚ setpoints‚ actual values‚ limitations‚ errors‚ etc.
  • Optional remote operation via room unit
  • 2 independent switching programs each with 3 occupancy times per day
  • Yearly clock with automatic summer- / wintertime changeover
  • Power and / or volumetric flow limitation in combination with heat meter
  • Pump and valve protection
  • Automatic monitoring of sensors with display of alarm
  • Locking function for district heat parameters
  • Optional suppression of hydraulic creep
  • Frost protection function
  • DRT limitation for the reduction of peak loads and of idle heat
  • Maximum limitation of the return temperature on the primary side
  • Minimum and maximum limitation of the flow temperature
  • Optimum start / stop control of the heating system
  • Automatic ECO function
  • Legionella function
  • Forced charging function for plant with storage tank
  • Cooling down protection for the primary supply lines
  • Solar d.h.w. heating
  • D.h.w. heating with electric immersion heater
  • Refill function
  • Selectable heating period

Plant-specific:

– Precontrol internal and interconnected
– 1 mixing or pump heating circuit
– D.h.w. heating with selectable priority:

  • Instantaneous systems
  • Storage charging system
  • Storage system with integrated heat exchanger
  • Circulating pump, 2 charging pump