RVL482

32,530,000 

  • SKU: RVL482
  • Mô tả: Heating controller for boiler temperature control for modulating or 2-stage burners with d.h.w. heating
  • Tình trạng: Hàng có sẵn, mới 100%
  • Chứng từ COCQ, tờ khai hải quan, có xuất hóa đơn VAT
  • Hãng sản xuất: Siemens
  • Giảm thêm 5% khi mua sản phẩm cùng danh mục có giá cao hơn
Chính sách ưu đãi CHÍNH SÁCH ƯU ĐÃI
Mua ngay
Mã: RVL482 Danh mục: Thương hiệu: Siemens

Thông số kỹ thuật RVL482

  • Operating voltage: AC 230 V
  • Frequency: 50 Hz
  • Power consumption: 9 VA
  • Analog inputs, number: 10
  • Analog outputs, number: 2
  • Digital inputs, number: 2
  • Digital outputs, number: 12
  • Relay output, switching voltage: AC 24…24 V
  • Relay output, switching current: 2 A
  • Mounting: Wall mounting
  • Degree of protection: IP42
  • Dimensions (W x H x D): 144 x 144 x 113 mm
  • Warranty: 24 Months

Mô tả sản phẩm

Key functions
Weather-compensated flow temperature control, with or without room influence, with simultaneous demand-compensated boiler and DHW control.
21 preprogrammed plant types can be selected from a combination of 5 heating applications and 4 DHW applications.

Heating circuit plant types

  • Control of space heating through control of a mixing valve in the heating circuit
  • Control of space heating through control of a mixing valve with simultaneous demand-dependent control of the boiler temperature
  • Control of space heating through control of mixing valve and boiler, plus minimum limitation of the boiler return temperature with own mixing valve
  • Demand-dependent control (precontrol) of the boiler temperature (heat demand signal via bus)
  • Demand-dependent control (precontrol) of the boiler temperature with minimum limitation of the boiler return temperature via mixing valve (heat demand signal via bus)

DHW plant types

  • Charging of DHW storage tank through control of a charging pump.
  • Charging of DHW storage tank through control of a mixing valve
  • DHW heating via heat exchanger through control of a 2-port valve in the primary return
  • DHW heating through electric immersion heater only
  • DHW heating with solar collector

Additional functions
In addition to the functions of the RVL480 and RVL481, the RVL482 offers the following functions:

  • 2 scalable DC 0…10 V inputs for heat demand signals from external consumers
  • Connection facility for solar and wind sensor (refer to chapter “Sensors”)
  • Control of a boiler or circulating pump
  • Optional selection of circulating pump/bypass pump
  • Three 7-day programs, each with 3 heating periods per day