RVL480

24,398,000 

  • SKU: RVL480
  • Mô tả: Heating controller for 1 heating circuit or boiler temperature control
  • Tình trạng: Hàng có sẵn, mới 100%
  • Chứng từ COCQ, tờ khai hải quan, có xuất hóa đơn VAT
  • Hãng sản xuất: Siemens
  • Giảm thêm 5% khi mua sản phẩm cùng danh mục có giá cao hơn
Chính sách ưu đãi CHÍNH SÁCH ƯU ĐÃI
Mua ngay
Mã: RVL480 Danh mục: Thương hiệu: Siemens

Thông số kỹ thuật RVL480

  • Operating voltage: AC 230 V
  • Frequency: 50 Hz
  • Power consumption: 7 VA
  • Analog inputs, number: 6
  • Analog outputs, number: 1
  • Digital inputs, number: 3
  • Digital outputs, number: 3
  • Relay output, switching voltage: AC 24…230 V
  • Relay output, switching current: 2 A
  • Mounting: Wall mounting
  • Degree of protection: IP42
  • Dimensions (W x H x D): 144 x 144 x 113 mm
  • Warranty: 24 Months

Mô tả sản phẩm

Key functions
Weather-compensated flow temperature control, with or without room influence
6 preprogrammed plant types are provided

Plant system

  • Control of a mixing valve serving a heating zone (space heating)
  • Control of a burner (1- or 2-stage)
  • Control of a valve in the primary return of a heating zone with district heat connection
  • Demand-dependent control (precontrol) of a mixing valve / of the boiler temperature / of a heat exchanger (heat demand signal via data bus)

Additional functions
The RVL480 offers the following functions (no submodules or extra devices required):

  • Display of parameters, actual values, operating states and fault status signals
  • 7-day program with 3 heating periods per day
  • 2 additional programs, each with 3 switching periods per day
  • Automatic summer/winter changeover
  • Holiday program (up to 8 holiday periods per year)
  • Optimum start/stop in accordance with the heating program (with or without room influence)
  • Automatic ECO function, depending on the outside temperature and the type of building construction
  • Optional remote selection of operating modes (via room unit or external switch)
  • Scalable DC 0…10 V output for passing on the heat request to other devices
  • Quick setback and boost heating
  • Preselection of flow temperature setpoint via external contact
  • Minimum and maximum limitation of the flow temperature
  • Minimum and maximum limitation of the return temperature (shifting / constant)
  • Maximum limitation of the room temperature
  • Communication with other devices via the data bus
  • Limitation of the return temperature differential (DRT) for district heat applications
  • Frost protection and pump protection
  • Flow temperature alarm